Resistance
|
Hydraulic fluids
|
Mineral oils
|
Mineral oil
|
HLP
|
according to DIN 51524
|
Resistant
|
Flame-resistant hydraulic fluids
|
Emulsions
|
HFA-E
|
according to DIN 24320
|
|
Water solutions
|
HFC
|
according to VDMA 24317
|
Phosphoric acid esters
|
HFD-R
|
Organic esters
|
HFD-U
|
Fast bio-degradable hydraulic fluids
|
Triglycerides (rape seed oil)
|
HETG
|
according to VDMA 24568
|
Synthetic esters
|
HEES
|
Polyglycols
|
HEPG
|
Electrical
|
Plug-in connection
|
4-pole M12 x 1 (material: metal) (K24)
4-pole (3 + PE) DIN EN 175301-803 (K14)
7-pole (6 + PE) DIN EN 175201-804 (K6)
|
Reed contacts of the float switches with connection K24, K14, K6/DC
|
Switching voltage range
|
V DC
|
10 … 36
|
Maximum switching current
|
A
|
0.5
|
Maximal contact load
|
VA
|
10
|
Temperature contacts of the float switches with connection K24, K14, K6/DC
|
Switching voltage range
|
V DC
|
10 … 50
|
Maximum switching current
|
A
|
0.5
|
Maximal contact load
|
VA
|
10
|
Maximum switching cycles
|
100000
|
|
Response tolerance
|
K
|
± 3
|
Hysteresis
|
K
|
≤10
|
Maximum temperature change velocity
|
K/min
|
1
|
Reed contacts of the float switches
with connection K14 according to DIN EN 175301-803 / K6 according to DIN EN 175201-804/AC
|
Switching voltage range
|
V AC/DC
|
10 … 230
|
Maximum switching current
|
A
|
0.5
|
Maximal contact load
|
VA
|
10
|
Temperature contacts of the float switches
with connection K14 according to DIN EN 175301-803 / K6 according to DIN EN 175201-804/AC
|
Switching voltage range
|
V AC/DC
|
10 … 230
|
Maximum switching current
|
A
|
2.5
|
Maximal contact load
|
VA
|
100
|
Maximum switching cycles
|
|
100000
|
Response tolerance
|
K
|
± 3
|
Hysteresis
|
K
|
≤10
|
Maximum temperature change velocity
|
K/min
|
1
|
Temperature sensor Pt100
|
Sensor element
|
|
Pt100 class B DIN EN 60751
|
Temperature measuring range
|
°C
|
0 … 100
|
Accuracy
|
K
|
± 0.8
|
Resistance measuring chain and resistance thermometer
with connection K24 for mating connector M12 x 1; 4-pole
|
Outlet 1)
|
mA
|
4 … 20
|
Resolution resistance measuring chain
|
mm
|
5
|
Maximum load resistance
|
|
(U ‒ 9 V) / (0.02 A)
|
Temperature measuring range
|
°C
|
0 … 100
|
Display and control unit
|
|
|
Power supply
|
V DC
|
10 … 32
|
Display range
|
°C
|
-20 … +120
|
Alarm adjustment range
|
Temperature
|
°C
|
0 … 100
|
Level
|
%
|
0 … 100
|
l
|
0 … 999
|
Switching points
|
4 programmable switching outputs (2 level + 2 temperature)
|
Housing design
|
PA, IP65 (antistatisch)
|
Current consumption upon switch-on
|
more than 100 ms
|
mA
|
≈ 100
|
Current consumption during operation
|
with UB 24 V
|
mA
|
≈50
|
Switching output
|
|
|
PNP
|
Maximum switching power
|
A
|
Maximum switching power
|
Switching output
|
|
|
3 keys
|
|
|
|
|
|
|
|
|
|
|